The CellaCombustion PX 47 is a special pyrometer for non-contact temperature measurement of sooty flames in coal-fired power plants or waste incineration plants. The measurement and signal processing based on the quotient method detects the thermal radiation of the sooty particles of the flame in the near infrared range at two wavelengths. A special algorithm is used to correct the influences of the wavelength-dependent radiation properties of the soot particles and the optical flame density when determining the temperature. The flame temperature can be used to control the burnout during combustion in order to reduce pollutant emissions and minimize slagging of the combustion chamber walls.
Pyrometer CellaCombustion PA 47
- Measuring range 700 to 1700 °C
- Modern IO-Link interface
- Focusable optics for exact adjustment of the measuring distance
- Broadband anti-reflective precision optics
- LED display can be read from a great distance
- Test current output for diagnostic function
- 1 analogue output and 2 switching outputs
- Source freely configurable
Version CellaCombustion PA 47 AF 1 /D Measuring range 700 - 1700 °C Focal distance 0,4 m - ∞ Shape of the measurement area round Distance ratio 80 : 1 Lens PZ 20.01 Measuring principle two-colour Sighting option Through-the-lens-sighting